中国科学院紫金山天文台机构知识库
Advanced  
PMO OpenIR  > 太阳高能及相关物理过程研究团组  > 期刊论文
题名: Prototype design of electronics readout system for solar gamma-ray spectrometer's high energy deposited
作者: Chen Wei; Guo Jianhua; Wang Shen
刊名: Nuclear Techniques(核技术)
出版日期: 2018
卷号: 41, 期号:2, 页码:20402
英文摘要: [Background] The large area solar gamma-ray spectrometer (LASGA) is a high-energy radiation detector that consists of anti-coincidence detectors and calorimeter. The calorimeter is composed of 5 orthogonal LaBr3 (lanthanum bromide) layers. Each layer includes fourteen 25 mm*25 mm*400 mm LaBr_3 crystals. To achieve large dynamic range, each LaBr_3 crystal matches with two independent readout elements with different gains. High gain readout uses a photomultiplier tube (PMT) while the low gain uses photodiode (PD). Since PD has no amplification capability for photoelectrons, the LASGA readout system requires a low-noise readout electronics system to achieve a high signal-to-noise ratio (SNR). [Purpose] This study aims to design an electronics prototype system with high dynamic range and low noise properties. [Methods] A 64-channel charge sensitive ASIC (VA140) produced by the IDEAS Inc. was used in front-end electronics board. And an Altera cyclone field-programmable gate array (FPGA) (EP3C25Q240C8) was employed to control the ASIC, analog to digital converter (ADC) and digital to analog converter (DAC) chips in data acquisition board. The digitalized detector signal was packaged in field-programmable gate array (FPGA) and sent to personal computer (PC) for processing. [Results] The performance of the electronics prototype was tested, while the minimum ionizing particles (MIPs) response of LaBr3 with cosmic ray muon was carried out as well. The test results showed that the noise level of the electronics system (@ 0 pF) and the detection system (connected with PD) at room temperature was about 600 e~- and 1 800 e~- respectively. And there was a good linearity in the range of 0-200 fC. The integral nonlinearity (INL) of 126 channels in the range of 0-180 fC was better than 3%. [Conclusion] Single bromide lanthanum unit can measure the energy deposited linearly up to 250 MeV. The dynamic range and SNR of the prototype system could fully meet the project's requirements.
语种: 英语
WOS记录号: CSCD:6186689
Citation statistics:
内容类型: 期刊论文
URI标识: http://libir.pmo.ac.cn/handle/332002/18045
Appears in Collections:太阳高能及相关物理过程研究团组_期刊论文

Files in This Item:
File Name/ File Size Content Type Version Access License
2018128.pdf(2765KB)期刊论文作者接受稿限制开放View 联系获取全文
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Chen Wei]'s Articles
[Guo Jianhua]'s Articles
[Wang Shen]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Chen Wei]‘s Articles
[Guo Jianhua]‘s Articles
[Wang Shen]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
文件名: 2018128.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2018  中国科学院紫金山天文台 - Feedback
Powered by CSpace